Core procedure

Four essential steps

  1. 01

    Design the enclosure, airlocks, baglocks and extraction capacity for the work and location.

  2. 02

    Smoke-test or otherwise verify integrity before asbestos work starts.

  3. 03

    Operate, inspect and record negative pressure and filtration performance throughout the work.

  4. 04

    Decontaminate and dismantle only after the required clearance stages are complete.